Sign In | Join Free | My disqueenfrance.com |
|
Brand Name : SUMT, ANT
Model Number : OMS-560-RHP-F-3T
Place of Origin : NINGBO CITY, CHINA
MOQ : MOQ:10sets
Price : USD80-150/PC
Payment Terms : T/T, Western Union, MoneyGram,Paypal
Supply Ability : 5000-1000pcs/month
Delivery Time : 3-20 working days depending on the quantity
Packaging Details : Box+carton, 10SETS/Carton, 22kg/carton, carton size: 38X31.5X32cm
Material : Stainless steel
Rated Load : max 3000kg
Voltage : DC19-29V
Cable length : 8m, 4 blank wire
Installation location : under the rope hitch plate
Display mode : Weight/percentage
Structure : Split type
Alarm relay output : 5(overload,full load,empty load, optical,acousti
SUMMIT Split type elevator overload control system 3000kg RHP-F-OMS-560 installed at elevator the rope hitch ;oint overload measurement control device
Installation loacation: installed at wire rope hitch point :OMS-560-RHP-F-3T(rated load: 3000kg)
Description:
The elevator over load control device OMS-560-RHP-F is one kind of split type load weighing solution ,and it consists of 1 or 2 pressure load sensor RHP-F and a controller OMS-560, and the pressure load cell is typically plated under the wire rope hitch plate. This method have no impact on the crossing height requirements and are there-fore especially suitable for new installation and modernization projects.
Features:
Control Unit:OMS-560 | |||
Operation Voltage | AC/DC16-48V | Sensor operation voltage | DC5V |
Nominal power | 4W | Signal Hold Voltage | AC/DC12-45V |
Input Channel (Load Cell ) | 2 | Measuring precision | 0.1% |
Relay Number | 5(overload,full,half empty,optical, audio output) | Operation temperature | -45degree-+85degree |
Contact Load | 8A250VAC,5A 250VAC,5A 30VDC | Size | 90x84x58mm |
Display Type | 4 digits 0.56 inch LED | Weight | 265g |
Display mode | Weight/percentage | Shell material | ABS |
Model: | RHP-F | ||
Rated Load | 3000kg/PC | Output Resistance | 700M+/-2 ohm |
Rated Output | 2.0+-0.02%mv/v | Safe Overload | 150% F.S. |
Total error | +/-0.5% F.S | Ultimate Overload | 200% F.S. |
Repeatability | +/-0.5% F.S. | Construction material | Stainless Alloy steel |
Creep 30min | +/-0.05% F.S/30min | Protection Class | IP68 |
Zero Balance | +/-1% F.S. | Insulation impedance | ≥5000Ω |
T C SPAN | +/-0.02% F.S./10 degree Celsius | Cable length | 8m(black) |
Operation temperature range | -30 to 70 degree Celsius | Connection type | 4 bank wire |
Input Resistance | 760+/-10 ohm | Excitation | DC 5-12V |
Wiring Diagram:
4 blank wires:
Installation location&Size:
Instruction:
The purpose of the SUMMIT Load Weighing system is to measure the load in the elevator and pro-vide usable information about the load to the elevator controller. This information is used forpre-torquing and for dispatching decisions, e.g. light load anti-nuisance, heavy load and over-load.
The system usually consists of a sensor or group of sensors mounted on the elevator’s some position such as clamping on wire rope, or under cabin, under the wire rope plate installation and a control unit. The sensor(s) provide a signal to the control unit directly related to the amount of load in the cab. The load weighing control accepts this signal and provides usable data to the elevator controller in the form of an analog signal and discrete relay contacts.
Using SUMMIT solutions loads can be weighed in every imaginable situation.We offer you flexible, modular solutions for both requirements, and wide experience with modernization projects. we attention to detail in the design of their modular system allows great freedom to configure load weighing systems to suit all types of cabin.
![]() |
SUMMIT Elevator Load Measuring System 3000kg RHP-F-OMS-560 Overload Measurement Control Device Images |